SGC Structure Quality Criteria

The quality criteria defined here are the minimal acceptance criteria for SGC structures; most structures are of considerably higher quality (Acta Crystallogr D Biol Crystallogr. 2007 63:941-50).

X-ray Crystallographic Structures

I- Resolution

II- Data Quality

III- Model quality

NMR Structures

I- Background

Unlike X-ray crystal structures there is no generally accepted R-factor or direct measure of resolution that can provide quantitative estimates of the quality or accuracy of NMR structures. Instead, NMR solution structures are reported as an ensemble of structures that satisfy the experimental data. The pairwise rmsd (in Å) between equivalent backbone atoms within the ensemble is often used as a rough measure of resolution or precision, however, this value is not equivalent to resolution as in an x-ray structure nor is it necessarily a measure of accuracy (given the dynamic nature of proteins in solution, and the "sparse" nature of NMR restraints). Given these limitations there are some generally agreed upon measures of structure quality that can be used to guide an NMR structure refinement. Below are a set of minimum quality requirements for SGC NMR structures.

II- Extent of Resonance assignment

A sufficient number of multidimensional, multinuclear NMR experiments should be collected (with sufficient resolution and S/N) to allow assignment of:

III- Assessment of Data Quality

IV- Structure quality